Product Description
ARMOR INSULATOR 200 is a premium heavy-duty, fire retardant, two-component closed-cell polyurethane Spray foam for building insulation systems. The product is generated on-site by combining an isocyanate and a polymeric resin through a dual-component
proportioner. Fast, easy and adaptable, it can achieve an R-value of 20 at 3 inches.
ARMOR INSULATOR 200 is a high density based polyurethane foam recommended for roofing and other exterior insulation because it is applied in a continuous manner.
- Superior Thermal Resistance – The R-value
of ARMOR INSULATOR 200 is higher than
traditional insulation products resulting in
reduced conductive heat loss and lower
energy consumption. - Excellent Air Sealing Ability – ARMOR
INSULATOR 200 is a closed cell insulation that
expands while being installed creating an
effective air barrier, reducing air leakage,
resulting in improved comfort and energy
savings. - Durability- INSULATOR 200 is a highly
durable and lasting insulation product. It
extends building life - Joint less – ARMOR INSULATOR 200
insulating material produces a seamless
insulating layer with no joints or gaps and
reduces energy loss due to thermal bridging - Seamless- Liquid” installation means that
critical, inaccessible or curved areas can be
insulated without any problem
Surface Preparation and Application
For optimum results, surfaces receiving ARMOR
INSULATOR 200 should be clean and dry, free of
dirt, oil, solvent, and grease, loose particulate,
peeling coating or other foreign matter. ARMOR
INSULATOR 200 adheres well without primer to
expanded polystyrene, extruded polystyrene,
foil-faced insulation boards, CMU and cured
concrete. Ferro metallic substrates (especially
mild steel) should be sand-blasted in
accordance with SSPC-SP6. Sand-blasted
surfaces should be immediately primed with
an epoxide primer as recommended by the
primer manufacturer. Galvanized and stainless
steel and aluminum substrates should be
treated with an appropriate ARMOR Primer
or adhesive prior to application of ARMOR
INSULATOR 200
ARMOR INSULATOR 200 is packed in 210kg and
225kg drums .Store in a cold dry place.
With
proper storage material can be stored and used
within 12 months.
ARMOR INSULATOR 200 is recommended for
use as insulation foam on the following areas:
Exterior Roof Insulation
Wall and floor Insulation
Armorsil provides detailed method statements
on all its products for use in various applications.
Below is an information summary for guidance
Surface Preparation and Application
For optimum results, surfaces receiving ARMOR
INSULATOR 200 should be clean and dry, free of
dirt, oil, solvent, and grease, loose particulate,
peeling coating or other foreign matter. ARMOR
INSULATOR 200 adheres well without primer to
expanded polystyrene, extruded polystyrene,
foil-faced insulation boards, CMU and cured
concrete. Ferro metallic substrates (especially
mild steel) should be sand-blasted in
accordance with SSPC-SP6. Sand-blasted
surfaces should be immediately primed with
an epoxide primer as recommended by the
primer manufacturer. Galvanized and stainless
steel and aluminum substrates should be
treated with an appropriate ARMOR Primer
or adhesive prior to application of ARMOR
INSULATOR 200
Conforms to the requirements of BS EN 934-2
Table 9
Appearance: White
Like all material that contains Portland cement,
this material must be handled professionally as
it can cause irritation and burns. Therefore
contact with skin and eyes must be avoided.
All recommendations, statements and technical data herein are based on tests we believe to be reliable and correct, but
accuracy and completeness of said tests are not guaranteed and are not to be construed as a warranty either expressed or
implied. User shall rely on his or her own information and tests to determine suitability of the product for the intended use and user assumes all risk and liability resulting from his or her use of the product. Nothing contained in any supplied materials relieves the user of the obligation to read and follow the warnings and instruction for each product as set forth in the current Technical Data Sheet, product label and Safety Data Sheet prior to product use away. Armorsil Manufacturing supplies products that comply with the properties shown on the current datasheets. In the unlikely event that products supplied are proved not to comply with these properties, then we will replace the non-compliant product or refund the purchase price. Armorsil Manufacturing does not warrant or guarantee the installation of the products as it does not have control over the installation or end use of the products. Any suspected defects must be reported to Armorsil Manufacturing in writing within seven working days of being detected. Armorsil Manufacturing. Makes no warranty as to merchantability or fitness for a particular purpose and this warranty is in lieu of all other warranties express or implied. Neither seller nor Armorsil Manufacturing shall be liable to the buyer or any third person for any injury, loss or damages of any sort including remote or consequential damages, down time, or delay directly or indirectly resulting from use of or inability to use the product. . The information contained in the latest data sheet supersedes all previously published editions. Visits to site by Armorsil personnel do not constitute supervisory responsibility. Armorsil reserves the right to alter the information contained in this datasheet without prior notice